Rating | 60 deg C, 30 Vac, Cable flame. |
|
Conductor | 40 AWG minimum. |
|
Insulation | Material not specified. Optional braid or fillers (material not specified) between conductor and insulation. |
|
Shield | Optional. |
|
Covering | Optional. PVC, 13 mils min at any point. |
|
Jacket | PVC. |
| Dia of cable under jacket | Minimum average | Minimum at any point |
| 0.250 inch or less | 15 mils | 12 mils |
| 0.251-0.424 inch | 30 mils | 24 mils |
| 0.425-0.700 inch | 60 mils | 48 mils |
| 0.701-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
| 2.501 inch or larger | 110 mils | 88 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection in Class 2 Circuits of electronic equipment where each end is terminated in connectors. |
|