APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1861 Issued:1982-03-25
Revised:2011-09-14
Style 1861 Single conductor with extruded insulation.

Rating80 deg C, 300 Vac, VW-1 flame.
Conductor32 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationTwo layers of PVC, total 26 mils minimum at any point. Inner layer: 13 mils minimum at any point. Outer layer: 7 mils minimum at any point, both minimum average not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances; or doubly protected internal wiring in television receivers and video products.