Rating | 80 deg C, 300 Vac, VW-1 flame. |
|
Conductor | 32 AWG - 16 AWG solid or stranded round, tinned or bare copper. |
|
Insulation | Two layers of PVC, total 26 mils minimum at any point. Inner layer: 13 mils minimum at any point. Outer layer: 7 mils minimum at any point, both minimum average not specified. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances; or doubly protected internal wiring in television receivers and video products. |
|