APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1869 Issued:1982-07-09
Revised:2011-07-29
Style 1869 Single Conductor with Extruded Insulation and Non-Integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor24 AWG - 18 AWG solid or stranded
InsulationSolid or cellular PE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldOptional.
JacketPVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024