APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1900 Issued:1983-07-11
Revised:2016-01-20
Style 1900 Single conductor with extruded insulation.

Rating200 deg C, 300 Vac.
Conductor30 AWG - 10 AWG, solid or stranded, silver plated, or nickel coated copper conductor or nickel conductor or tinned copper (tinned copper strands minimum 15 mils diameter); or nickel or nickel chrome alloy resistance conductor; or nickel-copper-iron alloy.
InsulationExtruded FEP, 10 mils minimum average thickness, 9 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor further processing into cables.