APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1912 Issued:1984-01-06
Revised:2012-11-30
Style 1912 Single-conductor cable with extruded non-integral jacket.

Rating90 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG minimum. Material not specified.
Insulationxtruded SRPVC, extruded foamed SRPVC, extruded XLSRPVC or extruded foamed XLSRPVC, 2 mils minimum thickness at any point, 100 mils maximum thickness
CoveringOptional. Extruded PVC, extruded Nylon, extruded ETFE, or extruded Polyester, 2 mils minimum thickness at any point, or lacquered braid.
ShieldOptional.
JacketOPtiona, same as covering.
ShieldOptional.
CoveringOptional. Extruded PVC, extruded Nylon, extruded ETFE, or extruded Polyester, 2 mils minimum thickness at any point, or lacquered braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024