APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1928 Issued:1984-07-26
Revised:2011-08-11
Style 1928 Single Conductor with Extruded Insulation and Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG - 18 AWG material not specified.
InsulationInner Layer - Extruded foamed PE or extruded foamed XLPE. Outer Layer - Extruded PE or extruded XLPE. Composite thickness 3 mils minimum thickness, 100 mils maximum thickness. (Two layers are non-separable.)
Inner ShieldOptional
CoveringOptional - PET or polyester tape wrap, minimum 0.7 mil thickness, applied with minimum 50 percent overlap.
Outer ShieldOptional
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits of electronic equipment, or External interconnection in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.

UL and the UL Logo are trademarks of UL LLC © 2024