APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1944 Issued:1984-11-27
Revised:2012-07-02
Style 1944 Single Conductor with Extruded Insualtion.

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG min. Material not specified.
InsulationExtruded FRPE, Foamed FRPE, Extruded XLFRPE, Foamed XLFRPE, Extruded PE, Foamed PE, Extruded XLPE, Foamed XLPE, Extruded SRPVC, or Foamed SRPVC, 2 mils minimum thickness at any point, 100 mils maximum thicknes.
AssemblyInsulated conductor is built with optional inner covering, optional shield, optional jacket, optional shield and optional outer covering.
ShieldOptional.
CoveringInner covering - (Optional) Extruded PVC, Nylon, ETFE, or Polyester 2 mils minimum thickness at any point, or lacquered braid. Outer covering - (Optional) same as inner covering.
Jacket(Optional) Same as Covering.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring Class 2.

UL and the UL Logo are trademarks of UL LLC © 2024