APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1947 Issued:1985-03-25
Revised:2012-07-25
Style 1947 Multiple conductor cable using non integral Jacketed.

Rating105 deg C, 600 Vac, Horizontal flame, Optional Oil Res 60 or 80 deg C , optional Moisture Resistant 75 deg C
Conductor26 AWG - 20 AWG solid or stranded copper.
InsulationPVC, 15 mils min average, 13 mils minimum at any point.
JacketExtruded Nylon , 4 mils min average.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring