APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1949 Issued:1985-07-03
Revised:2012-10-10
Style 1949 Multiconductor Cable with Extruded Non-Integral Jacket

Rating80 deg C, 150 Vac, Horizontal flame.
Conductor32 AWG - 14 AWG solid or stranded round, tinned, bare or silver plated copper, or solid or stranded coated high strength copper - min. 90% conductivity.
InsulationExtruded XLPVC, 10 mils min average, 8 mils minimum at any point.
ShieldOptional.
JacketExtruded PVC, 10 mils min average, 8 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024