APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1957 Issued:1985-12-26
Revised:2012-07-26
Style 1957 Single Conductor Cable with Extruded Insulation and Extrded Nonintregal Covering.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG min. solid or stranded round, tinned or bare copper.
InsulationExtruded Solid or Foamed FEP, 10 mils minimum at any point, 125 mils maximum.
ShieldOptional.
CoveringExtruded FEP or Extruded ETFE, 5 mils minimum at any point, 125 mils maximum.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and for further processing into multi-conductor cables.

UL and the UL Logo are trademarks of UL LLC © 2024