APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1966 Issued:1985-12-13
Revised:2011-10-16
Style 1966 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor32 AWG - 16 AWG solid or stranded.
InsulationExtruded PVC or Extruded XLPVC, 9 mils min average thickness, 7 mil min thickness at any point.
ShieldOptional.
JacketExtruded PVC or Extruded XLPVC, 9 mils min average thickness, 7 mil min thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor further processing in Cables for Electronic Equipment or Appliances.

UL and the UL Logo are trademarks of UL LLC © 2024