APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1978 Issued:1986-02-24
Revised:2011-09-26
Style 1978 Insulated Wire.

Rating200 deg C, 300 Vac, Horizontal flame.
ConductorResistance Wire.
InsulationFEP, 13 mils min average, 12 mils minimum at any point.
Assembly1 to 11 mil diameter single or paired resistance wire alloy spirally applied around a glass or aramid fiber core with a minimum of 20 turns per inch. May have helically wound glass fiber separator over conductor, and/or silicone rubber coating over core.
CoveringOptional. Lacquered glass braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as heating element in appliances where totally enclosed and where exposed to temperatures not exceeding 200 deg C.