| Rating | 200 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | Resistance Wire. |
|
| Insulation | FEP, 13 mils min average, 12 mils minimum at any point. |
|
| Assembly | 1 to 11 mil diameter single or paired resistance wire alloy spirally applied around a glass or aramid fiber core with a minimum of 20 turns per inch. May have helically wound glass fiber separator over conductor, and/or silicone rubber coating over core. |
|
| Covering | Optional. Lacquered glass braid. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | For use as heating element in appliances where totally enclosed and where exposed to temperatures not exceeding 200 deg C. |
|