APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1995 Issued:1986-09-30
Revised:2012-01-10
Style 1995 Single conductor with extruded insulation

Rating90 deg C, 150 Vac.
Conductor36 AWG min. material not specified.
InsulationPolyester, 7 mils min average thickness, 5 mils min thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs insulated singles in external interconnection wires and cable for electronic equipment. Tag may also indicate the following: "300 Volts Peak - For Electronic Use Only."