APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1996 Issued:1986-10-20
Revised:2013-02-07
Style 1996 Single-conductor cable using non-integral jacket

Rating80 deg C, 600 Vac, Horizontal flame.
ConductorThickness may vary from 0.05 mm to 0.12 mm, solid or stranded resistance wire alloy, or wound around a polyester core, number of turns not specified.
InsulationExtruded Foamed PE, 0.7 mm minimum average thickness, 0.6 mm minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC, 0.45 mm minimum average thickness, 0.35 mm minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseTest probe leads where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024