| Rating | 80 deg C, 600 Vac, Horizontal flame. |
|
| Conductor | Thickness may vary from 0.05 mm to 0.12 mm, solid or stranded resistance wire alloy, or wound around a polyester core, number of turns not specified. |
|
| Insulation | Extruded Foamed PE, 0.7 mm minimum average thickness, 0.6 mm minimum thickness at any point. |
|
| Shield | Optional. |
|
| Jacket | Extruded PVC, 0.45 mm minimum average thickness, 0.35 mm minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Test probe leads where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|