APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1998 Issued:1986-10-24
Revised:2012-03-19
Style 1998 Single Conductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationLabeled, Style 1061.
ShieldOptional.
JacketExtruded PVC, 8 mils minimum average thickness, 6 mil minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subjected to movement or mechanical damage, or for further processing into cables.