APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20001 Issued:1979-05-15
Revised:2012-07-20
Style 20001 Multiple Conductor with Extruded Insulation.

Rating60, 80, 90, 105 deg C, 30 Vac, VW-1 flame.
ConductorTwo 24-20 AWG.
InsulationExtruded PVC, 15 mils min average, 13 mils minimum at any point; web thickness and width not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2-circuits in Audio, Video and Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024