APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20005 Issued:1979-05-30
Revised:2012-04-30
Style 20005 Multiple conductor with extruded insulation

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum material not specified. May use same or mixed AWG sizes.
InsulationSolid or cellular FRPE or PE or PVC or XLPE or XLPVC, 2 mils minimum average thicness.
AssemblyTwo through 100 conductors. Insulated singles may be twisted or laid parallel to form round, flat or oval cable. Barrier and/or fillers optional.
ShieldOptional.
CoveringInner - Optional 2 mils minimum of - Extruded PVC, CoveringPolyamide, Polyester, Thermoplastic Polyvinyidence Fluoride Resin or Thermoplastic Copolymer of Ethylene and Tetrafluorethylene or lacquered braid .
JacketPVC, 2 mils min average 40 mils maximum.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.