APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20008 Issued:1979-06-12
Revised:2012-03-16
Style 20008 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating105 deg C, 125 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving; braid, nylon; polyethylene terephthalate (PET) or a thermoplastic jacket (4 mils minimum thickness at any point) or tape wrap. Such a barrier layer would serve to protect the cable during further processing and may be applied over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
CoveringOptional - Extruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point and may be extruded over the conductor assembly.
JacketExtruded XLPE
Diameter of core assembly under jacket (inches) ¿Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 inches or less3024
0.701-1.0004536
1.001-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024