APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20020 Issued:1979-10-01
Revised:2012-07-13
Style 20020 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, VW-1 flame.
Conductor40 AWG min, material not specified,
InsulationSolid or cellular PE or XLPE, 4 mils min at any point, 100 mils max.
AssemblyTwo, three or four conductors. May include barrier layer or fillers.
ShieldOver any and/or all singles.
CoveringOptional - Over any or all singles - 2 mils min at any point extruded PVC, polyamide, Polyester, PVDF, ETFE or Lacquered Braid.
JacketPVC, 5 mils min average, 3 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of Low Energy Nonhazardous Circuits in Audio and Video Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024