Rating | 60 deg C, 30 Vac, Horizontal flame, Cable flame test. |
|
Conductor | 40 AWG minimum, material not specified. |
|
Insulation | Solid or cellular PE, FRPE or XLPE, 5 mils min at any point, 100 mils maximum. |
|
Assembly | Two, three or four conductors |
|
Covering | Optional, Extruded PVC, polyamide, polyester, PVDF, ETFE, polyethylene or lacquered braid, 2 mils minimum at any point or spirally wrapped polyethylene tape, 1 mil minimum at any point. |
|
Shield | Optional. |
|
Inner Jacket | Extruded PVC, 3 mils minimum thickness at any point, 100 mils maximum thickness. 30 mils minimum thickness for external use; |
|
Outer Jacket | Optional, extruded PVC 30 mils minimum thickness, 100 mils maximum thickness. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or External wiring of Class 2 circuits in electronic equipment. |
|