Style 20026 Multiconductor cable with extruded non-integral jacket.

Rating60 deg C, 30 Vac, Horizontal flame, Cable flame test.
Conductor40 AWG minimum, material not specified.
InsulationSolid or cellular PE, FRPE or XLPE, 5 mils min at any point, 100 mils maximum.
AssemblyTwo, three or four conductors
CoveringOptional, Extruded PVC, polyamide, polyester, PVDF, ETFE, polyethylene or lacquered braid, 2 mils minimum at any point or spirally wrapped polyethylene tape, 1 mil minimum at any point.
ShieldOptional.
Inner JacketExtruded PVC, 3 mils minimum thickness at any point, 100 mils maximum thickness. 30 mils minimum thickness for external use;
Outer JacketOptional, extruded PVC 30 mils minimum thickness, 100 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or External wiring of Class 2 circuits in electronic equipment.