| Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 36 AWG - 18 AWG solid or stranded copper. |
|
| Insulation | Extruded PVC insulation singles bonded together, 8 mils min average, 6 mils min at any point after rip. |
|
| Assembly | Two through 150 conductors laid parallel. |
|
| Shield | Optional. |
|
| Covering | Optional - PVC, 5 mils min. at any point, 80 mils max. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of equipment, such as electronic computers and electric business machines. |
|