APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20036 Issued:1979-12-23
Revised:2012-03-21
Style 20036 Flat Cable

Rating75 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 16 AWG solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure, 8 mils minimum average thickness.
AssemblyMultiple layers of the insulated conductor assembly may be used providing the layers are separated by two mil minimum thickness polyester film.
ShieldOptional or shield may be braided aluminum faced polyester or metalized polyester tape with or without drain wire.
JacketExtruded PVC, 24 mils minimum average thickness, 100 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment, and business machines.