APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2004 Issued:1959-05-01
Revised:2012-07-26
Style 2004 Multi conductor cable with non-integral jacket

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor22 AWG Stranded.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point.
AssemblyFive conductor, same as Type SJT.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSee Facing Page for Limitations.

UL and the UL Logo are trademarks of UL LLC © 2024