APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20042 Issued:1980-02-04
Revised:2019-11-07
Style 20042 Multiple-conductor cable using non-integral jacket

Rating60, 80, 90 or 105 deg C, 300 Vac, Horizontal and Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more singles or twisted pair or triad or groups of twisted singles laid parallel to form flat/oval cable with more than three rows of single conductors or groups of nductors.
ShieldOptional.
JacketExtruded PVC
dia of cable under jacket
0.700 inches or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.000 dia110 avg99 min
4.001 dia or more140 avg126 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External interconnection of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024