APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20043 Issued:1980-02-15
Revised:2011-10-11
Style 20043 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded.
InsulationExtruded PVC, 15 mils mininum average thickness, 13 mils minimum thickness at any point.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional. Extruded PVC, 6 mil minimum thickness at any point, may be extruded over the conductor .assembly.
ShieldOptional.
JacketExtruded PVC, 15 mils mininum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment where not subjected to repeated flexing in end application.