APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20045 Issued:1980-02-15
Revised:2011-10-26
Style 20045 Multiple-conductor cable using non-intergal jacket.

Rating80 deg C, 30 Vac, VW-1 flame.
Conductor40 AWG minimum, solid or stranded.
InsulationExtruded solid PE, extruded foamed PE, extruded solid XLPE or extruded foamed XLPE, 4 mils minimum thickness at any point, 100 mils maximum thickness.
AssemblyTwo to four conductors. Barrier layer and/or fillers are optional.
ShieldBraid or spiral wrap construction using steel, nickel, tin, copper plated steel, copper plated iron alloy or copper plated nickel wires.
CoveringOptional, over any or all singles, extruded PVC, extruded Nylon (Polyamide), extruded Polyester, extruded PVDF, extruded ETFE or Lacquered Braid, 2 mils minimum thickness at any point.
JacketExtruded PVC, 5 mils minimum average thickness, 3 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring where not subjected to repeated flexing in end application.

UL and the UL Logo are trademarks of UL LLC © 2024