APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20046 Issued:1980-02-15
Revised:2011-10-06
Style 20046 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum Material not specified.
InsulationExtruded solid PVC, extruded foamed PVC, extruded solid XLPVC, or extruded foamed XLPVC. 4 mils minimum average thickness.
AssemblyTwo through seven insulated singles twisted together, length of lay not specified. Barrier layer and/or fillers optional. Fillers may be twisted with singles or insulated singles may be twisted around central filler core.
ShieldBraid or spiral wrap construction using steel, nickel, tin or copper-plated steel, or copper- plated iron alloy, or copper-plated nickel wires.
JacketExtruded PVC, 5 mils min average, 3 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wire of Class 2 Circuits in Electronic Equipment where not subjected to repeated flexing in end application.