APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20055 Issued:1980-05-08
Revised:2012-01-11
Style 20055 Bonded or laminated flat ribbon Cable

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor20-36 AWG, solid or stranded, tinned or bare copper, laid parallel spaced 0.025 inch minimum between conductors. One or more conductors may be in electrical contact with ground plane as drain wires.
InsulationPVC, 9 mils min. average, 7 mils min. at any point. Top and/or bottom layers may form ridges. Extruded or heat laminated.
AssemblyTwo through 150 conductors
ShieldOptional.
JacketPVC, 15 mils min average, 12 mils minimum at any point.
Misc.Ground-Plane Pressure sensitive aluminum faced polyester tape on one or both sides of insulated conductor assembly. May be in electrical contact with drain wire.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment, such as computers and electric business machines.

UL and the UL Logo are trademarks of UL LLC © 2024