APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20057 Issued:1980-06-03
Revised:2012-01-11
Style 20057 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 300 Vac, FT1 flame.
Conductor20 AWG - 14 AWG stranded, tinned or bare copper.
InsulationTPE, 30 mils min average, 27 mils minimum at any point.
AssemblyTwo to five conductors, same as type SJE Cord. Conductors shall be parallel, fillers may be omitted.
JacketTPE, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
Use"Internal Wiring of Double-insulated Electric Gardening Appliances, Lawn Mowers, or Snow Removers." Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024