APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20059 Issued:1980-06-16
Revised:2012-07-24
Style 20059 Laminated Flat Cable

Rating80 deg C, 30 Vac, Horizontal Flame.
Conductor36 AWG - 16 AWG, Solid or Stranded Round. May include mixed AWG sizes.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo to 100 insulated singles or twisted pair, laid parallel in one plane, laminated between 2 sheets of extruded PVC. Manufacturer shall maintain a record of all singles used in each cable. Min. 24 mils between singles, 12 mil min. edge width.
JacketNon-Extruded Laminated PVC, Two laminated sheets, 5 mils minimum average, 4 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.