APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20060 Issued:1980-06-27
Revised:2012-12-13
Style 20060 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 125 Vac, Horizontal flame.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
Conductor0.125 to 2.5 sq mm. Solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
CoveringOptional. Extruded PVC, 6 mils or heavier.
ShieldOptional.
JacketExtruded PVC.
Diameter of cable under jacket*Minimum average thicknessMinimum thickness at any point
0.350 inches or less15 mils12 mils
0.351-0.700 inches30 mils24 mils
0.701-1.000 inches45 mils36 mils
1.001-1.500 inches60 mils48 mils
*Major dia of cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024