Rating | 90 deg C, 120 Vac, Horizontal flame. |
|
Conductor | 22 AWG, consisting of 19 strands of 30 AWG, or 7 strands of 26 AWG.
Conductive Core - Carbon-loaded Radiated XLPE, 6 mils minimum thick. Distance between conductors 70 + 15 mils measured from center to center. Not evaluated as self-regulating heating core. |
|
Insulation | Extruded XLPE, 18 mils minimum average thickness at any point. |
|
Assembly | Two conductors with conductive core. Distance between conductors 70 +/- 15 mils measured from center to center. |
|
Misc. | Conductive Core - Carbon-loaded Radiated XLPE, 6 mils minimum thick. See facing page for compound. Distance between conductors 70 + 15 mils measured from center to center. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For use as refrigerator defrost heater or other heating applications. |
|