APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20064 Issued:1980-07-22
Revised:2012-04-25
Style 20064 Multiple conductor with extruded insulation.

Rating90 deg C, 120 Vac, Horizontal flame.
Conductor22 AWG, consisting of 19 strands of 30 AWG, or 7 strands of 26 AWG. Conductive Core - Carbon-loaded Radiated XLPE, 6 mils minimum thick. Distance between conductors 70 + 15 mils measured from center to center. Not evaluated as self-regulating heating core.
InsulationExtruded XLPE, 18 mils minimum average thickness at any point.
AssemblyTwo conductors with conductive core. Distance between conductors 70 +/- 15 mils measured from center to center.
Misc.Conductive Core - Carbon-loaded Radiated XLPE, 6 mils minimum thick. See facing page for compound. Distance between conductors 70 + 15 mils measured from center to center.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use as refrigerator defrost heater or other heating applications.

UL and the UL Logo are trademarks of UL LLC © 2024