APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20066 Issued:1980-07-18
Revised:2019-11-07
Style 20066 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 125 Vac, Cable flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional - A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
dia of cable under jacket
1.000 inches or less*30 mils min average24 mils min at any point
1.001-1.500 dia45 avg36 min
1.501-2.500 dia60 avg48 min
*Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment.