Rating | 250 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 18 AWG - 12 AWG stranded only. Heating Element - Nichrome, copper alloy or other suitable resistance wire is spirally wound around the insulation; the AWG size of wire, number of turns, length between contact with the copper conductor are dependent upon the wattage demand and the voltage used to energize the cable. |
|
Insulation | Extruded PTFE, TFE, 10 mils minimum average thickness, 9 mils minimum thickness at any point. |
|
Assembly | Two insulated conductors are laid parallel with an overall bonded 4 mil minimum thickness at any point wall of PTFE tape to form a SPT style cord. This cord is now prepared for the spiral wound heating element. This is done by care- fully removing the insulation along the length of the cord so as to bare the copper conductor for approx 1/2 in widths at periodic intervals. A spirally wound nichrome or other type of resistance wire is then carefully wound the length of the cord. By varying the distance between contacts with the conductors, the number of turns per inch of resistance wire and the AWG size (resistance) of the spirally wound wire, different wattages per foot per service voltage can be obtained. |
|
Covering | Optional. 16 mils minimum thickness at any point of bonded PTFE tapes. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Pipe heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|