APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20073 Issued:1980-07-30
Revised:2012-05-02
Style 20073 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, solid or stranded.
InsulationExtruded solid PE, solid FRPE, solid XLPE, solid XLFRPE, foamed PE, foamed FRPE, foamed XLPE or foamed XLFRPE, 5 mils minimum thickness at any point, 100 mils maximum thickness.
CoveringOptional - Extruded PVC, PE, Polyamide or Polyester, approximately 0.002 in. thick or lacquered braid, or spiral wrap of minimum 0.0006 inch thick polyester tape applied with approximate 50 percent overlap.
ShieldOptional.
AssemblyTwo to fifty insulated wires laid parallel in one plane, laminated between 2 sheets of PVC, with or without irradiation. Minimum 39 mils between conductors, 15 mils minimum edge width.
JacketExtruded PVC, 6 mils minimum average thickness, 5 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024