APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20079 Issued:2001-08-26
Revised:2012-07-13
Style 20079 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG min, material not specified.
InsulationExtruded ETFE or FEP, 1 mils min at any point.
AssemblyTwo or three insulated conductors, twisted or parallel.
ShieldOptional.
CoveringOptional - Inner - Extruded FEP or ETFE, 2 mil min at any point. Outer - Extruded FEP or ETFE 4 mils min average, 3 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment in Class Circuits Only.