			| Rating | 80 deg C, 30 Vac, Cable flame. | 
			|  | 
			| Conductor | 40 AWG min., solid or stranded round. May use same or mixed AWG size. | 
			|  | 
			| Insulation | Labeled or complying with manufacturer's AWM procedure. | 
			|  | 
			| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. | 
			|  | 
			| Shield | Optional. | 
			|  | 
			| Covering | Optional - A 6 mil or heavier Extruded PVC covering may be extruded over the conductor assembly. | 
			|  | 
			| Jacket | Extruded PVC | 
			|  | dia of cable under jacket | 
			|  | 0.425 inches or less* | 30 mils min average | 24 mils minimum at any point | 
			|  | 0.426-0.700 dia | 45 avg | 36 min | 
			|  | 0.701-1.000 dia | 60 avg | 48 min | 
			|  | 1.001-1.500 dia | 80 avg | 64 min | 
			|  | 1.501-2.500 dia | 110 avg | 88 min | 
			|  | 2.501 dia and larger | 140 avg | 112 | 
			|  | *Major dia if cable is flat or oval. | 
			|  | 
			| Standard | Appliance Wiring Material UL 758. | 
			|  | 
			| Marking | General. | 
			|  | 
			| Use | Internal wiring and external interconnection of electronic equipment, Class 2 circuits only. | 
			|  |