APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20082 Issued:1980-09-03
Revised:2019-11-07
Style 20082 Multiple conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Conductor40 AWG min., solid or stranded round. May use same or mixed AWG size.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional - A 6 mil or heavier Extruded PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
dia of cable under jacket
0.425 inches or less*30 mils min average24 mils minimum at any point
0.426-0.700 dia45 avg36 min
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
1.501-2.500 dia110 avg88 min
2.501 dia and larger140 avg112
*Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment, Class 2 circuits only.

UL and the UL Logo are trademarks of UL LLC © 2024