APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20084 Issued:1980-08-18
Revised:2012-03-07
Style 20084 Multiple-conductor cable using non-integral jacket

Rating60 deg C, voltage not specified, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional. A 6 mils or heavier PVC covering may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded TPU
* Dia of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less45 mils36 mils
0.701 - 1.500 inch60 mils48 mils
*major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment (such as a TV camera).