APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20086 Issued:1980-09-24
Revised:2012-06-08
Style 20086 Laminated flat ribbon cable.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG - 4 AWG bare, silver plated, tin plated or nickel plated copper, round or flat. Minimum width 20 mils, maximum width 2-1/2 inches. Minimum thickness 1 mil, maximum thickness 15 mils. Conductors may be straight or irregular shaped.
InsulationPET, 1.5 mils minimum thickness at any point.
Assembly2 through 100 conductors, PET bonded together with minimum 40 mils insulation width on outside edges of conductors and 28 mils minimum width insulation between adjacent conductors. Length of insulated conductors not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment and/or appliances.

UL and the UL Logo are trademarks of UL LLC © 2024