APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20087 Issued:1980-10-06
Revised:2012-03-23
Style 20087 Multiple-conductor cable using non-integral extruded jacket.

Rating75 deg C, 120 Vac, Horizontal flame.
ConductorConstructuon A - Two or three, 0.002 by 0.010 inches, flat copper ribbons wound spirally, 11 to 20 turns per inch, over a rayon or polyester core. Construction B - One or two No. 32-35 AWG copper conductors wound spirally, 11 to 20 turns per inch, over a rayon or polyester core. Sensor (Optional) - Stainless steel fiber located between the conductive core and the insulation. Not evaluated as a Sensor.
Conductive coreTwo conductors laid parallel within the carbon-loaded polyethylene, thickness not specified.
InsulationExtruded EVA or extruded PVC, 13 mils min average, 12 mils minimum at any point. See facing page for EVA compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Bedding.

UL and the UL Logo are trademarks of UL LLC © 2024