APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2009 Issued:1959-05-01
Revised:2011-09-23
Style 2009 Three-Conductor Style SPT-2 Cord.

Rating80 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor20 AWG - 16 AWG Stranded, tinned or bare copper.
InsulationIntegral with Jacket. PVC, 45 mils min average, 40 mils minimum at any point.
AssemblyThree conductor, same as Type SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of lighting circuits in electric refrigerators where exposed to temperature not exceeding 80 deg C; or Internal wiring of lighting circuits in electric refrigerators where exposed to temperatures not exceeding 80 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C whichever is applicable). Polarity identification may be omitted.