| Rating | 105 deg C, Voltage rating not specified, Cable flame. |
|
| Conductor | 36 AWG - 10 AWG. May use same or mixed AWG size. |
|
| Insulation | Labeled or complying with manufacturers procedure. |
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. |
|
| Shield | Optional. |
|
| Covering | Optional - Extruded PVC, 6 mil or heavier thickness. May be extruded over the conductor assembly. |
|
| Jacket | Extruded PVC |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inches or less | 60 mils | 48 mils |
| 0.701-1.500 inchs | 80 mils | 64 mils |
| 1.501-2.500 inchs | 110 mils | 88 mils |
| 2.501 inchs or greater | 140 mils | 112 mils |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | External interconnection of electronic equipment. |
|