APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20092 Issued:1980-12-11
Revised:2019-11-07
Style 20092 Multiple conductor cable using non-integral jacket

Rating60, 80, 90 deg C, 150 Vac, Cable flame.
Conductor36 AWG - 18 AWG solid or stranded copper.
InsulationPP, 8 mils min average, 7 mils min at any point.
AssemblyTwo to 100 conductors individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketPVC
dia of cable under the jacket
0.395 inches or less30 mils min average24 mils minimum at any point
0.396-0.500 dia35 avg30 min
0.501-0.700 dia50 avg43 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal or internal wiring use.