APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20095 Issued:1981-01-02
Revised:2012-11-16
Style 20095 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor30 AWG - 20 AWG.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point. Center conductor - extruded PVC. Other conductor - not insulated.
AssemblyThe uninsulated conductor is either laid parallel or twisted with the insulated conductor and jacket is extruded over the assembly.
JacketExtruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring in Class 2 circuits of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024