APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20097 Issued:1981-01-06
Revised:2012-03-16
Style 20097 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 150 Vac, Horizontal flame.
Conductor33 AWG - 18 AWG stranded, round or tinsel, tinned or bare. May include mixed AWG sizes.
InsulationExtruded POLYESTER, 7 mils minimum average thickness, 5 mils minimum thickness at any point. See Facing Page for compound designation.
AssemblyTwo to ten conductors. Cable may be either straight or wound in retractile form. Core may be either flat or round. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs "Handset Wire or Telephone Cord for Subscriber Sets".