Rating | 60 deg C, 150 Vac, Horizontal flame. |
|
Conductor | 33 AWG - 18 AWG solid or stranded round. |
|
Insulation | Extruded PVC, 8 mils minimum average thickness, 6 mils minimum thickness at any point. |
|
Assembly | Two to ten conductors, may include mixed AWG sizes. Cable may be either straight or wound in retractile form. Core may be either flat or round. Barrier layer and/or fillers optional. |
|
Shield | Optional. |
|
Jacket | Extruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal cable of electronic equipment. |
|