APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20098 Issued:1981-01-06
Revised:2011-12-13
Style 20098 Multi-conductor Cable with Extruded Non-Integral Jacket.

Rating60 deg C, 150 Vac, Horizontal flame.
Conductor33 AWG - 18 AWG solid or stranded round.
InsulationExtruded PVC, 8 mils minimum average thickness, 6 mils minimum thickness at any point.
AssemblyTwo to ten conductors, may include mixed AWG sizes. Cable may be either straight or wound in retractile form. Core may be either flat or round. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal cable of electronic equipment.