APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20100 Issued:1981-01-08
Revised:2012-04-26
Style 20100 Single-conductor cable with extruded non-integral jacket.

Rating125 deg C, 300 Vac, Horizontal flame.
Conductor16 AWG - 10 AWG solid or stranded round, tinned or bare copper.
InsulationExtruded TPE, 60 mils minimum average thickness, 54 mils minimum thickness at any point before separation, 27 mils minimum thickness at any point after separation. See facing page for compound.
AssemblyTwo conductors, same as type SPE-3. Over the insulated conductors, an adhesive-backed copper tape 0.125 inch by 0.0025 inches thick is applied as a band at periodic intervals with the adhesive side down against the PVC insulation. Dependent of the AWG size of the SPT-3 conductor, a staple made of "monel" metal or stainless steel is driven through the insulation of one of the copper conductors and over the adhesive-backed copper tape at a slight angle to the conductor. The staple will protrude through the insulation and the points are bent over on the underside. A nichrome or other alloy resistance wire is then spirally wound around the cord and the copper banding tape. The number of turns per inch will determine the watts per foot of heating cable. A second tape of either adhesive-backed copper of TFE tape is then wrapped over the heating element wire and the "monel" staple completely covering the first copper tape. This assembly is repeated alternately along the conductor. The second tape covering is simply to hold down the resistance wire and make contact with the "monel" staple and first copper tape.
JacketExtruded TPE, 40 mils minimum average thickness, 32 mils minimum at any point, applied overall. See facing page for compound.
ShieldOptional.
CoveringOptional, Extruded TPE, 13 mils minimum thickness at any point, see Facing Page for Compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024