APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20103 Issued:1981-01-18
Revised:2012-05-02
Style 20103 Multiple-conductor cable using non-integral jacket with extruded insulation

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum, solid or stranded.
InsulationExtruded solid PVC, solid PE, solid FRPE, solid XLPVC, solid XLPE, solid XLFRPE, foamed PVC, foamed PE, foamed FRPE, foamed XLPVC, foamed XLPE or foamed XLFRPE, 5 mils minimum thickness at any point, 100 mils maximum.
Assembly2 - 31 insulated singles. Insulated singles laid parallel to form flat cable.
ShieldOptional - Conductive thermoplastic (PVC) shield, if used, may form a web between conductors under jacket and will include one or more drain wires covered by thermoplastic shield.
CoveringOptional.
JacketTwo laminated sheets, PVC or XLPVC, 5 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.