APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20109 Issued:1981-02-10
Revised:2012-12-13
Style 20109 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, VW-1 flame.
AssemblyTwo, three or four conductors.
Conductor30 - 14 AWG. Solid or stranded.
InsulationExtruded PE, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring in Radio and Television Receiver, Audio Systems and Accessories.