APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20110 Issued:1981-02-24
Revised:2012-07-27
Style 20110 Multiple Conductor Cable with Extruded Insulation with an Extruded Non-intergal Jacket.

Rating90 deg C, 250 Vac, Horizontal flame, Moisture Resistant 75 deg C, 720hr Sunlight Resistance.
ConductorNickel, copper alloy or copper, Size varies for each conductor depending upon wattage demand.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point. QMTT2 PVC suitable for 75 deg C Wet, THWN (UL83) or see facing page for compound.
AssemblyThree conductors, same as type SPT. May be spirally wound around a thread core. See facing page for compound.
ShieldBraid consisting of 34 AWG min bare or tinned copper, providing 80 percent coverage.
CoveringOptional.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point. R/C (QMTT2) suitable for 720hr Sunlight Resistant or see facing page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHeating Cable.

UL and the UL Logo are trademarks of UL LLC © 2024